Ceramic vessel 3 close to grave 233. Cemetery of La Noria.

Ceramic vessel 2 close to grave 233 (burial mound H) of the Iberian cemetery of La Noria (Fuente de Piedra, Málaga, Spain). Oxidising atmosphere.
The MRS analysis did not provide conclusive data, but the EDXRF analysis indicates the presence of Mn at a prominent concentration: 1.48% wt. The black color would therefore have been obtained with a manganese oxide, which in this case has not been identified.

New product

Dimensions

: 9.5 Centimeters

: 13 Centimeters

Materials

pottery

Temporal

: Iberian, Iberians

: Late 6th ct. BC-early 5th ct. BC

Spatial

: Cemetery of La Noria

: Fuente de Piedra, Málaga, Spain

: WGS84

 

Copyrights

Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND)

References

Resolución de 18 de noviembre de 2008, de la Dirección General de Bienes Culturales, por la que se incoa el procedimiento para la inscripción en el Catálogo General del Patrimonio Histórico Andaluz, como Bien de Interés Cultural, con la tipología de Zona Arqueológica, la necrópolis protohistórica de La Noria, en Fuente de Piedra, Málaga.

Andrino, M., Sánchez, P. J., Cumpían, A. y López, S. (2008):“Una necrópolis de incineración de las etapas iniciales de la Edad del Hierro en la comarca de Antequera. Resultados de la intervención arqueológica de urgencia en la parcela ur-6, Fuente de Piedra, Málaga”. Varia, 9. 359-378.

Digital Resources

Activities

Archaeometric analysis

Physical-chemical analysis

Ceramic. Analysis of decoration

University Research Center for Iberian Archaeology

X-Ray Fluorescence

Elemental analysis of black decoration.

Non destructive. Surface cleaning. Sample pretreatment is not required. Direct measurement.

Energy dispersive X- ray fluorescence (EDXRF)

EDAX (model Eagle III) fluorescence spectrometer (CITI, University of Seville). This spectrometer is equipped with a microfocus X-ray tube with an Rh anode, a polycapillary lens for X-ray focussing, and an 80 mm2 energy dispersive Si-(Li) detector. The sample chamber incorporates an XYZ motorized stage for sample positioning. A high resolution microscope is used to position the sample on the desired distance from the polycapillary. To increase the sensitivity of the low Z elements, the sample chamber can be brought under vacuum. For the analysis of the samples, a spot size of 300 μm was chosen at an operating X-ray tube voltage of 40 kV. The tube current was adapted for each sample in order to optimise the detection of X-rays

 