Ceramic vessel 1-04. Oppidum Los Turruñuelos

Ceramic vessel from the Iberian oppidum Los Turruñuelos (Úbeda-Villacarrillo, Jaén, Spain). The site was linked to the battle of Baécula during the 2nd Punic War (208 BC). Oxidising atmosphere. Decoration with red band and red concentric circles. The red colour is manufactured using hematite (Fe2O3) in vey high concentration (43.38% wt of Fe according to the EDXRF analysis). The use of an extra amount of iron ore to be added to the clay mix used for decoration is proposed.

New product

Dimensions

: 10 Centimeters

: 7 Centimeters

Materials

pottery

Temporal

: Iberian, Iberians

: 4th-3rd ct. BC.

Spatial

: Oppidum Los Turruñuelos

: Úbeda-Villacarrillo, Jaén, Spain

: WGS84

 

Copyrights

Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND)

References

Bellón, J. P.; Ruiz, A. Molinos, M; Rueda, C. y Gómez F. (eds.) (2015): La Segunda Guerra Púnica en la Península Ibérica. Baecula: arqueología de una batalla. Textos CAAI 7. Universidad de Jaen. Jaén.

Digital Resources

Activities

Archaeometric analysis

Physical-chemical analysis

Ceramic. Analysis of decoration.

University Research Center for Iberian Archaeology

Raman Microscopy

Mineral analysis of the red decoration

Non destructive. Surface cleaning. Sample pretreatment is not required. Direct measurement.

Micro-Raman Spectroscopy (MRS)

Renishaw ‘in via’ Reflex Spectrometer coupled with a confocal Leica DM LM microscope (CICT, University of Jaén), equipped with a diode laser (785 nm, 300 mW), and a Peltier-cooled CCD detector, calibrated to the 520.5 cm-1 line of silicon.

X-Ray Fluorescence

Elemental analysis of red decoration

Non destructive. Surface cleaning. Sample pretreatment is not required. Direct measurement.

Energy dispersive X- ray fluorescence (EDXRF)

Espectrómetro de fluorescencia de rayos X de energía dispersiva EDAX (modelo Eagle III)( CITI, Universidad de Sevilla). Está equipado con un tubo de rayos X microfocus con un ánodo de Rh, una lente policapilar para enfoque de rayos X y un detector de energía dispersiva Si-(Li) de 80mm2. La cámara de medida incorpora una bandeja motorizada para el posicionamiento de la muestra. Microscopio de alta resolución para posicionar la muestra a la distancia adecuada. Cámara con bomba de vacío para elementos de bajo número atómico (Z). Para un tamaño del área de medida de 300 μm se selecciona en el tubo de rayos X un voltaje de 40kV. La intensidad de corriente del tubo se adapta a cada muestra para optimizar la detección de los rayos X.;

 