Ceramic vessel 113-1. Oppidum Puente Tablas

Ceramic vessel of the sanctuary of the Iberian oppidum of Puente Tablas (Jaén, Spain). Oxidising atmosphere. Decoration with black lines. The black color is manufactured using a oxide of manganese identified by MRS as bixbyite/hausmannite (Mn2O3/Mn3O4) and jacobsite (MnFe2O4). Bixbyite/hausmannite are the result of the transformation of pyrolusite when firing temperature is set above 450ºC and below 900ºC. The presence of jacobsite means a temperature reaching the 900ºC.
Analysis by EDXRF of the black color confirms the presence of Mn: 0.73% wt of Mn versus 0.07% wt in the ceramic paste.
Leer más Leer menos

New product

Dimensions

: 5 Centimeters

: 6 Centimeters

Materials

pottery

Temporal

: Iberians, Iberian

: Early 4th ct. BC

Spatial

  • : Oppidum de Puente Tablas
  • : Puente Tablas, Jaén, Spain
  • : WGS84
 

Copyrights

Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND)

Digital Resources

Activities

  • Archaeometric analysis
  • Physical-chemical analysis
  • Ceramic. Analysis of decoration

University Research Center for Iberian Archaeology

Raman Microscopy

Mineral analysis of the black decoration

Non destructive. Surface cleaning. Sample pretreatment is not required. Direct measurement.

Micro-Raman Spectroscopy (MRS)

Renishaw ‘in via’ Reflex Spectrometer coupled with a confocal Leica DM LM microscope (CICT, University of Jaén), equipped with a diode laser (785 nm, 300 mW), and a Peltier-cooled CCD detector, calibrated to the 520.5 cm-1 line of silicon

X-Ray Fluorescence

Elemental analysis of the black decoation

Non destructive. Surface cleaning. Sample pretreatment is not required. Direct measurement.

Energy dispersive X- ray fluorescence (EDXRF);

EDAX (model Eagle III) fluorescence spectrometer (CITI, University of Seville). This spectrometer is equipped with a microfocus X-ray tube with an Rh anode, a polycapillary lens for X-ray focussing, and an 80 mm2 energy dispersive Si-(Li) detector. The sample chamber incorporates an XYZ motorized stage for sample positioning. A high resolution microscope is used to position the sample on the desired distance from the polycapillary. To increase the sensitivity of the low Z elements, the sample chamber can be brought under vacuum. For the analysis of the samples, a spot size of 300 μm was chosen at an operating X-ray tube voltage of 40 kV. The tube current was adapted for each sample in order to optimise the detection of X-rays.;

 

30 other products in the same category:

Menu