New product
: 5 Centimeters
: 4.5 Centimeters
pottery
: Iberian, Iberians
: 5th ct. BC
: Oppidum de Puente Tablas
: Puente Tablas, Jaén, Spain
: WGS84
Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND)
Ruiz A. y M. Molinos (coord.) (2015): Jaén, tierra ibera. 40 años de investigación y transferencia. Universidad de Jaén.
Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND) Arquiberlab http://creativecommons.org/licenses/by-nc-nd/3.0/ |
Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND) Arquiberlab http://creativecommons.org/licenses/by-nc-nd/3.0/ |
Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND) Arquiberlab http://creativecommons.org/licenses/by-nc-nd/3.0/ |
Number of analyses: 2
Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND) Arquiberlab http://creativecommons.org/licenses/by-nc-nd/3.0/ |
Number of analyses: 2
Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND) Arquiberlab http://creativecommons.org/licenses/by-nc-nd/3.0/ |
Number of analyses. Red decoration: 3, black decoration: 5, ceramic paste: 2
Creative Commons - Attribution, Non-Commercial, No Derivatives (BY-NC-ND) Arquiberlab http://creativecommons.org/licenses/by-nc-nd/3.0/ |
Archaeometric analysis Physical-chemical analysis Ceramic. Analysis of decoration
| |
Raman Microscopy Mineral analysis of the red and black decoration Non destructive. Surface cleaning. Sample pretreatment is not required. Direct measurement. Micro-Raman Spectroscopy (MRS) Renishaw ‘in via’ Reflex Spectrometer coupled with a confocal Leica DM LM microscope (CICT, University of Jaén), equipped with a diode laser (785 nm, 300 mW), and a Peltier-cooled CCD detector, calibrated to the 520.5 cm-1 line of silicon. | |
X-Ray Fluorescence Elemental analysis of the red and black decoration Non destructive. Surface cleaning. Sample pretreatment is not required. Direct measurement. Energy dispersive X- ray fluorescence (EDXRF) EDAX (model Eagle III) fluorescence spectrometer (CITI, University of Seville). This spectrometer is equipped with a microfocus X-ray tube with an Rh anode, a polycapillary lens for X-ray focussing, and an 80 mm2 energy dispersive Si-(Li) detector. The sample chamber incorporates an XYZ motorized stage for sample positioning. A high resolution microscope is used to position the sample on the desired distance from the polycapillary. To increase the sensitivity of the low Z elements, the sample chamber can be brought under vacuum. For the analysis of the samples, a spot size of 300 μm was chosen at an operating X-ray tube voltage of 40 kV. The tube current was adapted for each sample in order to optimise the detection of X-rays. |